Bucher Hydraulics DVSA−1L... serie size 1 trykkbegrensningsventiler - Patron

Bucher Hydraulics trykkventiler
  • Can be used as a pilot valve
  • Compact construction for cavity type AL - 3/4-16 UNF
  • Operated by a proportional solenoid
  • In a power failure, the pressure setting drops to the minimum value
  • 5 pressure ranges available
  • All external parts zinc plated, chromited (CrVI−free)
  • High pressure wet−armature solenoids
  • The slip−on coil can be rotated, and it can be replaced without opening the hydraulic envelope
  • Various plug−connector systems and voltages are available
  • Can be fitted in a line−mounting body
          Bucher Hydraulics DVSA−1L... serie size 1 trykkbegrensningsventiler - Patron
Kontakt Hydex vedrørende Bucher Hydraulics DVSA−1L... serie trykkbegrensningsventiler

Type      Proportional Pressure−Relief Cartridge Valve, Size 1
Designation Proportional pressure−relief cartridge valve
Design Pilot valve, seated design, direct acting
Mounting method Screw−in cartridge 3/4−16 UNF
Size Nominal size 1, cavity type AL
Cavity type thread
Max operating pressure Main port 2: 420 bar
Port 1: 250 bar
Max flow rate 1,5 l/min
Flow direction 2 → 1, see symbol
Hydraulic fluid Mineral oils HL and HLP to DIN 51 524;
for other fluids, please consult BUCHER
Hydraulic fluid
temperature range
−25°C ... + 70 °C
Viscosity range 15...380 mm²/s (cSt), Recommended 20...130 mm²/s (cSt)
Minimum fluid cleanliness 18/16/13 to ISO 4406 : 1999
For mer informasjon Datablad --- Oversikt

Kontakt Hydex vedrørende Bucher Hydraulics DVSA−1L... serie trykkbegrensningsventiler 


Relaterte produkter

Bucher Hydraulics DVSA−1LG... serie size 1 trykkbegrensningsventiler - Patron       Bucher Hydraulics WUVA−1LO... serie size 1 trykkbegrensningsventiler - Patron
  
Oversikt Bucher Hydraulics trykkbegrensningsventiler - Patron
  
 
Page rendered: 28.12.2022 22:02:08
OXX.Authorization.User.Username: Hydex_Systemhydraulikk_anonym (NO)