Type |
|
Pressure−Relief Cartridge, Size 10 mm |
|
|
Designation |
|
Pressure−relief cartridge with two electrically selected pressures |
|
|
Design |
|
Two-stage, seated pilot, spool−type main stage, soleniod controlled |
|
|
Mounting method |
|
Screw−in cartridge (M24 x 1,5) |
|
|
Size |
|
Nominal size 10, cavity type DD |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
315 bar |
|
|
Max flow rate |
|
120 l/min |
|
|
Flow direction |
|
A → B, see symbol |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 60 °C |
|
|
Viscosity range |
|
10...300 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/14 to ISO 4406 / CETOP RP70H, 8...9 to NAS 1638 |
|
|
For mer informasjon |
|
Oversikt |
|
|