Type |
|
Pressure−Relief Cartridge Valve, Size 10 mm |
|
|
Designation |
|
Pressure relief cartridge valve |
|
|
Design |
|
Poppet pilot stage, spool main stage with integral spool type bypass check valve |
|
|
Mounting method |
|
Screw−in cartridge (M24 x 1,5) |
|
|
Size |
|
10 mm nominal size, BUCHER cavity type DC |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
350 bar in A and B |
|
|
Max flow rate |
|
100 l/min |
|
|
Flow direction |
|
A → B, see symbol |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 60 °C |
|
|
Viscosity range |
|
10...300 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/14 to ISO 4406 /CETOP RP70H 8 ... 9 to NAS 1638 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|