Type |
|
Inverse Proportional Pressure−Relief Cartridge, Size 10 |
|
|
Designation |
|
Inverse proportional pressure−relief cartridge |
|
|
Design |
|
Seated pilot, spool−type main stage, damped design |
|
|
Mounting method |
|
Screw−in cartridge (M24 x 1,5) |
|
|
Size |
|
Nominal size 10, cavity type DC |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
300 bar in main port A 250 bar in port B |
|
|
Max flow rate |
|
120 l/min |
|
|
Flow direction |
|
A → B, see symbol |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 70 °C |
|
|
Viscosity range |
|
15...380 mm²/s (cSt), recommended 20...130 mm2/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|