Type |
|
Proportional Pressure Reducing Valve, Size 7 |
|
|
Designation |
|
Proportional pressure−reducing valve |
|
|
Design |
|
Sandwich design, electrically operated, seated pilot stage |
|
|
Mounting method |
|
4 x ∅ 10.5 holes for M10 cap screws 2 x ∅ 7 holes for M6 cap screws |
|
|
Size |
|
Size 07 interface to ISO 4401−07−07 / DIN 24 340 A16 |
|
|
Interface |
|
|
|
|
Max operating pressure |
|
350 bar in port P Unpressurized in port Y |
|
|
Max flow rate |
|
250 l/min |
|
|
Flow direction |
|
See symbols |
|
|
Hydraulic fluid |
|
HL and HLP mineral oils to DIN 51 524, for other fluids please contact BUCHER |
|
|
Hydraulic fluid temperature range |
|
- 25°C ... + 70 °C |
|
|
Viscosity range |
|
15...380 mm²/s (cSt), recommended 20 ... 130 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 : 1999 |
|
|
For mer informasjon |
|
Klikk her --- Oversikt |
|
|